AeroScope AFM6000
Air Flow Meter for flow rates up to 6000 l/min
The solution for measuring high air flow rates
The AeroScope AFM is a reliable and precisely working air flow meter that can be operated with the VacuScope comfort testing devices for milking installations and with the VacuScope easy pulsation meters.
Despite its large measuring range of up to 6000 l/min, the AeroScope AFM 6000 is so compact that it can even be used at measuring locations that are difficult to access.
Continuously adjustable air inlet
By simply turning the sleeve of the unit, the air inlet can be adjusted continuously. Doing so, the desired vacuum level can be choosen precisely.
Expandable measuring range
To test larger systems with the VacuScope comfort, the measuring range of a connected AFM6000 can optionally be extended up to 10,000 l/min using additional air flow orifices (not contained in standard scope of delivery). These orifices are usually connected at multiple points so that large air flow rates are evenly distributed over the entire system. This arrangement offers advantages over test equipment offering only a single measuring tube.
Automatic vacuum correction
When measuring with a VacuScope device and a connected AeroScope unit, the measurement result is automatically adjusted to the vacuum level. Automatic correction takes place within a wide range from 25 to 50 kPa. This provides precise measurements directly without the need for manual recalculation and the use of correction tables.
Robust and easy to use
The robust construction of the device ensures a long service life even in harsh environments. Power is supplied via the data cable through the VacuScope base unit, so a separate power supply unit is not required.
Ordering information
We look forward to receiving your inquiry about this item:
| Stock code | Description |
|---|---|
| KUBAFM6/STD | AeroScope AFM 6000 - Air Flow Meter supporting up to 6000 l/min |
Downloads + Links
Technical Data
- Measuring medium: atmospheric air
- Measuring range (at 50 kPa)
AFM6000: 500 ... 6000 l/min - Resolution: 1 l/min
- Measuring accuracy:+/- 5%
- Interface type: RS232
- Power supply: 5..6 VDC / 25 mA
(via data cable from VacuScope) - Length of connection cable: approx. 140 cm
- Service interval: 12 months
- Dimensions: approx. 15 x 11 x 18 cm (without cable)
- Weight: approx. 950 g